Distribution of Stress of nFA/PEEK Biomaterials in Dental Implant

Lu GAN,Jie WEI,Dong-mei WANG,Jian MA
DOI: https://doi.org/10.3969/j.issn.1005-4979.2015.05.007
IF: 1.9
2015-01-01
Journal of Oral and Maxillofacial Surgery
Abstract:Objective:To analyze distribution of stress surrounding poly-ether-ether-ketone bio-composited by nano-fluorap-atite (nFA/PEEK) dental implant under static loading. Methods:A 3-D mandible bone first molar region segment was mod-eled, nFA/PEEK and titanium alloy implants were established. Three-dimensional finite element analysis method was simu-lated to check distribution of stress under 180 N and 240 N static loadings, which were decomposed into vertical, buccolin-gual and mesiodistal directions. Results:Stress around implant abutment of buccolingual stress was higher than that of verti-cal and mesiodistal, which nFA/PEEK was 4.2 times lower than that of corresponding Ti 6Al4V. Stress of nFA/PEEK was con-centrated at the 1/3 neck area, which was less than Ti6Al4V. Stress of nFA/PEEK implant bone bed were located in 10 mm areas around the neck, which was higher than that of Ti6Al4V. Von-mises value calculated between 20~60 Mpa were found in a sorted as 240 N vertical Ti6Al4V>180 N mesiodistal or 240 buccolingual nFA/PEEK>240 N vertical Ti6Al4V>180 N buccol-ingual and 240 N nFA/PEEK>240 N vertical nFA/PEEK. Conclusion:nFA/PEEK in abutment is not easy to be broken un-der physiological masticatory force. A higher nFA/PEEK bone stress calculated between 20~60 MPa is reduced in extent of stress shielding effect, which is beneficial to cortical bone deposition and is potentially a promising implant material.
What problem does this paper attempt to address?