Clinical study on the management of refractory glaucoma by Ex-press filtration device implantation

He Cheng,Fanrong Meng,Xinghuai Sun,Zhan Liu,Renyi Wu
DOI: https://doi.org/10.3760/cma.j.issn.1006-4443.2016.03.015
2016-01-01
Abstract:Objective To investigate the efficacy and safety of a stainless steel glaucoma filtration device (Ex-press P50) for the surgical treatment of refractory glaucoma.Methods Twenty-nine eyes of 31 patients diagnosed as refractory glaucoma were treated with Ex-press glaucoma filtration device implantation.The visual acuity and intraocular pressure were compared before and after operation;the postoperative complications were observed.Results The postoperative mean follow up was (12.9±4.4) months.The intraocular pressure was markedly reduced form a preoperative mean of (34.9±9.2mmHg) to a postoperative mean of (15.6±4.8mmHg) at one year,the difference had statistically significant (t =11.117,P <0.001).The postoperative success rate was 87.1% (27/31) and the complete success rate was 77.4% (24/31) at one year;the serious complications weren't happened.Conclusions The Ex-press implantation is a safe and effective method for refractory glaucoma with open anterior chamber.
What problem does this paper attempt to address?