Dose and volume factors to the acute radiation-induced heart disease
何宏涛,王军,刘青,王祎,龙书敬,程云杰,景绍武,尚凯,曹峰
DOI: https://doi.org/10.16073/j.cnki.cjcpt.2014.10.002
2014-01-01
Abstract:OBJECTIVE:To evaluate the relationship between dose-volume histogram parameters of the heart and the acute radiation-induced heart disease(RIHD)in patients with thoracic tumors.To evaluate the cut-off value of the dosevolume histogram parameters by ROC curve.METHODS:A total of 57patients with lung cancer and 52patients with esophageal carcinoma received three-dimensional conformal radiotherapy(3D-CRT)or intensity modulated radiotherapy(IMRT).The PTV dose ranged from 50Gy to 64Gy,delivered in 1.8Gy to 2.0Gy per fraction,5times per week.The dose distribution of target and organs at risk were analyzed by 3-dimensiond treatment planning system.The heart status were evaluated before treatment,and the acute RIHD was observed at the end of the irradiation and within 90days since the irradiation began,respectively.Common Terminology Criteria for Adverse Events,3.0version was applied to assess the acute RIHD.The relationship between dose-volume histogram parameters of the heart and the acute radiation-induced heart disease(RIHD)was evaluated.RESULTS:The incidence of RIHD was 79.8%(87/109).Among them,73cases were in grade 1,and 14cases were in grade 2.There were 5cases(4.6%)with pericardial effusion,54cases(49.5%) with abnormal electrocardiogram,serum troponinⅠand myocardium creatase increased in 14cases(12.8%)and 26cases(23.9%).The max dose(Dmax)and the mean dose to the heart(MHD)were(61.264±15.160)Gy and(21.305± 12.796)Gy.The volume of the heart exposed to 5Gy irradiation(V5),V10,V20,V30,V40,V50,V60of the heart were(64.6±32.9)%,(56.4±33.6)%,(43.3±30.5)%,(31.6±24.4)%,(21.7±18.8)%,(12.4±11.5)%,(5.5±6.5)%, and the dose of the heart exposed to 5% volume(D5),D50,D100 were(49.450±18.907)Gy,(17.206±14.568)Gy,(2.820±3.715)Gy,respectively.Heart NTCP was 10.7±17.6.The studies showed that the V60and normal tissue complication probability(NTCP)of the heart were higher in acute RIHD group than that in normal group(t=-2.140,P= 0.032,and t=-2.088,P=0.037).Receiver operator characteristic curve(ROC curve)analysis was used in order to find the appropriate threshold for V60and NTCP of the heart,the area under ROC curve were 0.747and 0.675,which meant the accuracy of the prediction was medium and up to medium,the cut-off points were 5.04%and 1.5.Logistic multivariate analysis showed that V60of the heart was the independent influencing factor to the acute RIHD(P=0.012).CONCLUSIONS:V60and NTCP of heart are the main influencing factors to the acute RIHD,and V60is the independent influencing factor.The acute radiation injury incidence would be increased significantly when the V60is over 5.04%.Tolerated dose to pericardial seems to be lower than those reported in the literature.