Simultaneous Determination of 3 Components in Euodiae Fructus by HPLC WaVelength Switching Technology

Lisha Shen,Guoqing Chen,Fan Yang,Kaiying Deng
2015-01-01
Abstract:Objective To develop an HPLC method for simultaneous determination of 3 components in Euodiae Fructus. Methods A C18 column ( 250 mm × 4. 6 mm, 5 μm ) was used with the mobile phase of acetonitrile-0. 2% phosphoric acid ( 35:65 ) with the flow rate of 2. 0 mL/min and the column temperature was 30 ℃. The detection wavelength was set at 205 nm for Evodine in the first 15. 01 min, and then changed to 225 nm for evodiamine and rutaecarpine between 15. 01 and 28 min. Results The linear ranges of evodine, evo-diamine and rutaecarpine fell within the ranges of 0. 186~3. 72 μg, 0. 040 24~0. 804 8 μg, 0. 040 08~0. 801 6 μg, respectively ( r=0. 999 7,0. 999 9,0. 999 9 ) . The average recoveries were 96. 30%, 97. 66% and 97. 46% with RSD were 1. 43%, 1. 32% and 1. 80%, respectively( n=6). Conclusion The method is convenient,quick,accurate and suitable for the qulity control of Euodiae Fructus.