Determination of Valine, Leucine, Isoleucine, Phenylalanine and Tyrosine in Human Serum by a HILIC-MS/MS Method Using Stable Isotope-labeled Amino Acids as Internal Standards

Hui-wen JIAO,Xu-dong XIAO,Lu-ning SUN,Li-yuan YU,Zi-qing-yun YUAN,Hong-wen ZHANG,Hong-wen ZHOU,Yong-qing WANG,Zheng-yu YAN
DOI: https://doi.org/10.13664/j.cnki.pcr.2016.04.007
2016-01-01
Abstract:Objective: To establish an HILIC-MS/MS method for the simultaneous determination of va-line, leucine, isoleucine, phenylalanine and tyrosine in human serum. Methods: The five corresponding sta-ble isotope-labeled amino acids were used as the internal standards. For serum samples, acetonitrile was used as the precipitant. Chromatographic separation carried on a Syncronis HILIC column (150 mm×2.1 mm, 5μm). The gradient elution mobile phase was consisted of acetonitrile and 80 mmol·L-1 ammonium acetate solution. Results: We used the stable isotope-labeled amino acids instead of unlabeled amino acids to study the matrix effects and recovery in human serum. The matrix effect was 90.3%-108.3%, while the re-covery was 89.6%-106.4%. Calibration curves and quality control samples were prepared by spiking the corresponding unlabeled amino acids in water. All the analytes showed good linearity over their concentra-tion ranges. The accuracy, inter- and intra-batch precision were all within 15%. Analytes were stable dur-ing the study. Conclusion: A simple and selective HILIC-MS/MS method has been successfully developed for the simultaneous determination of valine, leucine, isoleucine, phenylalanine and tyrosine in human serum.
What problem does this paper attempt to address?