Abstract:OBJECTIVE To study the purification of artemisinin by silica gel column chromatography conducted after the supercritical fluid extraction.METHODS Thin layer chromatography- silica gel column chromatography was used to analyze the effect of different mobile phases and confirm the best mobile phase (n-hexane:ether =8020) (by volume). And the effects of flow rate, sample load ,and the regenerated condition were further researched on the purity and the recovery of artemisinin.RESULTS The optimal operation conditions were flow rate 0.5 cmmin~(-1), sample load 18.9 mgml~(-1). The silica gel column might be regenerated by 2 bed volumes of methanol. The purity of artemisinin could be improved from 15% to more than 70% after purification, and the recovery was 90%. The purity of artemisinin could be further reached 99.5% by recrystallization.CONCLUSION After the process of silica gel column chromatography,the artemisinin can meet the demand of the market.