Determination of Loratadine in Human Plasma by High Performance Liquid Chromatography-Electrospray Mass Spectrometry and Studies on Its Pharmacokinetics and Relative Bioavailability

Jun Chen,Kepan Gao,Zhengqi Shi,Wei Lu,Xinguo Jiang,Zhengxing Rong,Xia Huang,Hongzhuan Chen
2002-01-01
Journal of Chinese Pharmaceutical Sciences
Abstract:A new HPLC-MS method to determine loratadine in human plasma was established. The method involved extracting drug with organic solvent under basic conditions. The samples were seperated by ODS column and determined by recovery of this method was within 95% ~ 104%, within day and between day RSD were less than 12%. To study the pharmacokinetics and relative bioavailahility of loratadine tablets, two formulations of loratadine tablets were given to 18 healthy male volunteers according to a randomized 2-way cross-over design. The Cmax, AUC0-t and Tmax values of the two formulations mL-1; 0.81 ± 0.35 h and 0.81 ± 0.27 h respectively. Results from statistic analysis showed that there were no significant difference between the Cmax, AUC0-t and Tmax values of the two formulations. The relative bioavailahility of tablets I with respect to tablets Ⅱ was 97% ± 13% from the AUC0-t measurement. Bioequivalance was observed between the two tablets.
What problem does this paper attempt to address?