Evaluation of the tracing effect of carbon nanoparticles and methylene blue combined with 99 Tcm-sulfur colloid in endoscopic sentinel lymph node biopsy for breast cancer
Yongsong Zhang,Quankun Liang,Ling Zhong,Yi Zhang,Li Chen,Linjun Fan,Jun Jiang
DOI: https://doi.org/10.3877/cma.j.issn.1674-0807.2015.04.002
2015-01-01
Abstract:Objective To explore the application effect of 99 Tcm-sulfur colloid combined with carbon nanoparticles or methylene blue in endoscopic sentinel lymph node biopsy ( ESLNB) in breast cancer patients. Methods From March 2014 to December 2014, a total of 80 breast cancer patients were randomly divided into two equal groups ( n=40 ) . Both groups underwent ESLNB. One group received carbon nanoparticles plus 99Tcm-sulfur colloid tracing sentinel lymph node (SLB) (nanocarbon group) and the other group received methylene blue plus 99Tcm-sulfur colloid tracing SLB (methylene blue group). After operation, the detection rate of SLB, positive rate and postoperative complications were compared between two groups. Measurement data were expressed as xˉ±s and processed by independent sample t test. The count data were compared by χ2 test or Fisher exact test. Results The detection rate of sentinel lymph nodes was 100% ( 40/40 ) in nanocarbon group and 97. 5% ( 39/40 ) in methylene blue group respectively. The mean number of detected sentinel lymph nodes per patient was 3. 4 ± 1. 5 in nanocarbon group and 3. 2 ± 1. 5 in methylene blue group respectively, indicating no significant difference between two groups (t=0. 984,P=0. 326). The positive rate of sentinel lymph nodes was 32. 5% (13/40) in nanocarbon group and 25. 6% (10/39, one did not detect the SLN) in methylene blue group respectively, indicating no significant difference between two groups (χ2 =0. 450,P=0. 502). Totally 116 non-sentinel lymph nodes were detected in nanocarbon group, mean (3. 2 ± 1. 1) per patient (range:2-5), including 57 black-stained lymph nodes (49. 1%). In methylene blue group, 97 non-sentinel lymph nodes were detected, mean (2. 8 ± 1. 1) per patient (range 1-5), including 26 blue-stained lymph nodes ( 26. 8%) . The number of detected non-sentinel lymph nodes per patient and stain rate showed significant differences between two groups(t=2. 632, P=0. 009,χ2=11. 079,P=0. 001). There was no significant difference in postoperative complication rate between two groups (P=0. 660). Conclusions Carbon nanoparticles or methylene blue combined with 99 Tcm-sulfur colloid show a beneficial tracing effect in SLNB for breast cancer patients, with the advantages of high detection rate, minimal trauma, small surgical scar and less complications. However, Carbon nanoparticles are helpful to detect non-sentinel lymph nodes, which can be useful as tracers for axillary lymph node dissection.