Successful TSRH Spinal System Instrumentation and Pressed Graft for Thoracolumbar Spine Fractures

李明,刘培来,刘洪智,刘庆福
DOI: https://doi.org/10.3969/j.issn.1671-7554.2002.02.017
2002-01-01
Abstract:Objective : To research on TSRH spinal instrumentation and pressed graft for thoracolumbar spine fractures. Methods: Instrumentation with TRSH spinal system and pressed grafts were adopted to treat 18 patients with thoracolumbar spine fractures. Plain roentgenography was performed before and after surgery, and during the latest follow up. Computed tomography was also performed before and during the latest follow up .The improvement to body collapse and narrowing of canal were calculated through measurements of anterior and posterior body heights, Cobb angle and of midsagittal diameter of canal. Results: All patients were followed up of 19 30 months, most of whom had an anatomic alignment. There was minimal loss of reduction but no broken screws during the follow up period. Excellent result was achieved in 10 cases, good in 5 and fair in 3. Overall outcome was satisfactory. Conclusions: TSRH and pressed grafts for thoracolumbar spine fractures provided satisfactory maintenance of correction.
What problem does this paper attempt to address?