Abstract:Purpose To study intraoperative changes of corrected left ventricular ejection time in the off-pump coronary bypass surgery. Methods Twenty patients scheduled for off-pump coronary bypass surgery were studied.Esophageal Doppler monitor was used in every patients after induction.Corrected left ventricular ejection time and hemodynamic data were collected before pericardial incision (T1),during left anterior descending artery grafting (T2),during posterior descending artery grafting (T3) and during obtund marginal artery grafting (T4).Trend of corrected left ventricular ejection time was studied and influence factors were also explored. Results Corrected left ventricular ejection time decreased significantly during obtund marginal artery grafting.It correlated with cardiac output throughout the whole anastomosis period,and inversed with systemic vascular resistance during obtund marginal grafting. Conclusions Corrected left ventricular ejection time may trace changes of preload indirectly.However,large dose of vasoconstrictors will impact on its effectiveness.