Three-dimensional Echocardiography for Quantifying Left Ventricular Volumes in Canine after Coronary Occlusion

YANG Jun-hua,SHI Ya-ming,ZHOU Bing-yuan,YANG Xiang-jun,JIANG Ting-bo,SONG Jian-ping,ZHAO Cai-ming,XIAO Bin,LIU Zhi-hua
DOI: https://doi.org/10.3969/j.issn.1008-8199.2005.z1.005
2005-01-01
Abstract:Objective : This study was designed to compare the accuracy of three- and two-dimensional echocardiography for quantifying left ventricular end-diastolic volumes (LVEDV) , and to test the reproduc-ibility of three-dimensional echocardiography for measurement of LVEDV. Methods:Coronary ligation was performed in 11 open chest dogs. Two-and three-dimensional echocardiography were performed to measure LVEDV 4 hours after coronary occlusion, and the results were compared with those of fluid method. The three-dimensional echocardiographic date set was processed, and quantitative dates were derived weeks apart for evaluating intraobserver variability. Another investigator analyzed the date for obtaining interob-server variability. Results:Three-dimensional echocardiographic measurements of LVEDV correlated more closely with LW of fluid method ( r = 0. 98, SEE±1. 69 ml) than did the two-dimensional Simpson' s method ( r = 0. 87, SEE±4.62 ml). Analysis of intra- and interobserver variability showed strong indexes of agreement in the measurement of LVEDV with three-dimensional echocardiography. Conclusion: For geometrically asymmetric left ventricular volumes associated with acute myocardial infarction, volume-rendered three-dimensional echocardiography can quantitatively measure left ventricular volume.
What problem does this paper attempt to address?