Contrastive analysis of oxidated regenerated cellulose and absorbable gelatin sponge on the hemostasis during ACDF procedure

Nan LI,Bo LIU,Da HE,Yong-gang XING,Gui-lin ZHANG,Wei TIAN
DOI: https://doi.org/10.3969/j.issn.1002-266X.2014.44.013
2014-01-01
Abstract:Objective To compare the hemostatic effect between oxidated regenerated cellulose ( ORC) and absorba-ble gelatin sponge ( AGS) during anterior cervical discectomy and fusion procedure ( ACDF) .Methods 356 patients un-derwent the ACDF procedure were divided into ORC group (191 patients) and AGS group (165 patients).The operative duration, the volume of blood loss and the volume of drainage between two groups were compared.Results The average operative duration in ORC and AGS groups was (81.5 ±9.9) min and (88.6 ±10.8) min (P=0.062).The average op-erative blood loss in ORC and AGS groups was (55.3 ±11.2) mL and (69.4 ±13.2) mL (P=0.034).The average post-operative drainage in ORC and AGS groups was (35.5 ±13.5) mL and (51.2 ±16.8) mL (P=0.029).One pa-tient in AGS group underwent exploration due to acute neck hematoma post-operatively.Conclusion Compared with AGS, ORC can obviously decrease the operative blood loss and drainage, increase the safety of operation.