Hai-yan ZHANG,Jun-ya CHEN,Yu SUN,Hui-xia YANG
DOI: https://doi.org/10.3969/j.issn.1008-1070.2015.07.011
2015-01-01
Abstract:Objective To value the indications , methods and safety of the cordocentisis . Method Between January 2012 and December 2014, 303 cordocenteses were performed in 303 women with singleton pregnancy in the Peking University First Hospital . A 22-gauge percutaneous needle was used to puncture the umbilical vein at the relatively fixed position with the “free-armed” method. Result 91. 8%(278/303) procedures were performed to identify the fetal karyotype. But only 10. 5% (16/153)of the karyotypes of the fetuses with obvious abnormalities are abnormal. Three cases whose chromosomal karyotypes were mosaics by amniocentesis had normal karyotypes by cordocentesis. 92. 4%(280/303) cases just needed one puncture. The gross fetal loss rate after cordocentesis was 1. 32%(4/303), and the fetal loss rate in two weeks was 0. 99%(3/303), the fetal bradycardia rate was 3. 0%(10/303). Conclusion Cordocentesis is a relatively safe prenatal surgery. The most important indications for the procedure should be the diagnosis and treatment for fetal anemia, and the identification for the karyotypes of the fetuese with chromosomal mosaic by amniocentesis, as well as the chromosome karyotype analysis. But new laboratory methods should be performed to investigate the genetic anomalies for the fetuses with structural abnormalities.