Effect of clamping drainage tube for four hours on postoperative blood loss in patients underwent total knee arthroplasty

宋黄鹤,范卫民,刘锋,陈哲锋,周锦春
DOI: https://doi.org/10.19460/j.cnki.0253-3685.2015.08.005
2015-01-01
Abstract:Objective To observe the effect of clamping drainage tube for 4 hours on postoperative blood loss in the patients underwent total knee arthroplasty (TKA ) .Methods Sixty patients underwent TKA were equally assigned into two groups .The drainage tube in group A was clamped soon after surgery for 4 hours ,which in group B was opened all the time .The blood loss , hospital stay and complications were observed and compared between two groups .Results The postoperative blood loss in 24 hours was significantly less in group A than that in group B [(512.4 ± 253.5)ml vs .(873.4 ± 301.5) ml](P<0 .05) .The percentage of patients needed blood transfusion after operation was significantly lower in group A than that in group B (46.7% vs .90.0% ) (P<0 .05) .The decrease of Hb after operation was less in group A than that in group B in the cases without blood transfution [(15.5 ± 7.2) g/L vs .(21.8 ± 10.3) g/L](P<0 .05) .There were no significant differences in fever ,wound healing and rehabilitation between two groups .Conclusion Clamping drainage tube for 4 hours may effectively reduce postoperative blood loss in the patients underwent TKA without increasing the risk for infection and rehabilitation .
What problem does this paper attempt to address?