Determination of Chlorpromazine and Promethazine Residues in Swine Kidney

FAN Sheng-xian,HUANG Ling-li,YUAN Zong-hui,Chen Pin
DOI: https://doi.org/10.3969/j.issn.1005-4545.2005.04.026
2005-01-01
Abstract:A high-performance liquid-chromatographic method was developed for determination of chlorpromazine and promethazine in swine kidney. The sample pre-treatment involves extraction with acetonitrile, and purification with acidic acetonitrile and n-hexane followed by evaporation with nitrogen and dissolution with methanol. The samples were detected with waters HPLC system including UV detertor and 515 pump. The mobile phase was acetonitrile∶water∶0.5 mol/L ammonium acetate(50∶49∶1) with the flow velocity of 1.2 mL/min. The result showed that the limit of detection was 10 μg/kg for chlorpromazine and promethazine. The average recovery was over 80% with intra-day coefficience of variation less than 20%. This method was accurate and feasible enough with simple pre-treatment for detection of the residues of chlorpromazine and promethazinein in swine kidney.
What problem does this paper attempt to address?