A Study of the Stable pH Value of Doxycycline Hydrochloride Injection

Hai-yan HU,Yi-lin WANG,Yao-ling HUANG,Qian XU,Shi-xin XU,Xin-le ZHU,Ming-wen ZHU
2014-01-01
Abstract:The stable pH value of the veterinary doxycycline hydrochloride injection was predicted. The chemical stability of doxycycline hydrochloride injection was studied in the extensive pH range by classical isothermal kinetic method and single point kinetic method. The relationship between stability and pH value of the injection was investigated. The results showed that, the most stable pH value and stable pH range that predicted by the two methods were basically identical. The most stable pH value of doxycycline hydrochloride injection was 4.0. Single point kinetic method was simple and its workload was small compared with the classical kinetic method.
What problem does this paper attempt to address?