Heat preservation and ventilation effect of the speed control tunnel ventilation in the rabbit house in winter

Shaobiao GE,Dan LIU,Zhongying LIU,Peng LIU,Yingkai YAN,Qi LI,Zhonghong WU
2017-01-01
Abstract:The speed control tunnel ventilation of rabbit house in Qingdao was tested to find out the heat preservation and ventilation effect in winter.The results showed that as the average and minimum outdoor temperature were-2.3 ℃ and-2.9 ℃,the average and minimum indoor temperature,CO2 and NH3 concentration of the breeding rabbit house were 10.4 ℃,9.5 ℃,0.16% and 6.88 mg/m3,respectively.In addition,the average and minimum indoor temperature,CO2 and NH3 concentration of the breeding rabbit house and commodity rabbit house were 8.0 ℃,7.2 ℃,0.15% and 6.08 mg/m3,respectively.The temperature,humidity and concentration distribution of harmful gases were evenly distributed,and the air distribution was good.The fresh air temperature through the curtain air inlet increased by 7.3 ℃ and 6.4 ℃ in the two rabbit houses.The CO2 and NH3 concentration obviously decreased with ventilation rate increased (P<0.01).Furthermore,the change of NH3 was gentle and obvious lagging.During the experiment,the estrous rate (93.3%),fetal rate (94.0%),yield rate (87.0%) and the litter number (8.1) were all higher.Therefore,when added the wind deflector in the pad air inlet and used the frequency conversion fans to provide minimum ventilation rate in the tunnel ventilation system,it could solve the problem of cold daft around the air inlet form a uniform temperature humidity and air flow distribution,and the air quality of the rabbit house was considerably improved.