Vibration of single-story masonry structures induced by subway through in-situ tests

JIN Hao,LIU Weining,ZHOU Shunhua,YUAN Yang,YU Kaiwen
DOI: https://doi.org/10.3969/j.issn.1672-7029.2017.02.018
2017-01-01
Abstract:In order to analyze vibration characteristics of the single-story masonry structures nearby metro lines, vertical and horizontal acceleration on the floor of the single-story masonry structure was tested in Beijing. Furthermore, the vertical acceleration of different positions on the street near the tested masonry structure was tested as well. Through the weighted acceleration levels on the floor of the tested masonry structure, the modified values between the tested masonry structure and the tested street were obtained. Based on the modified values, the weighted acceleration levels of different positions in the street were modified. Finally, the calculation formula was derived, which can calculate the floor vibration of the single-story masonry structure in different distances with the metro line.
What problem does this paper attempt to address?