Analysis for Drive Circuit and Improved Current Controller for Proportional Amplifier

XU Bing,SU Qi,ZHANG Jun-hui,LU Zhen-yu
DOI: https://doi.org/10.3785/j.issn.1008-973x.2017.04.022
2017-01-01
Abstract:The lager tracking error will appear when tracking a reference input near zero by the classical proportion-integrated controller because the current character of the inverse discharging drive circuit is nonlinear.A mathematical model was proposed to carefully describe the piecewise nonlinearities in the inverse discharging type drive circuit in order to solve the problem.A test setup was built for the model validation.A novel current controller was designed based on the analysis results.The innovation of this controller includes the dead zone compensation and the anti-wind up design, which is proposed to quickly skip the nonlinear part of the drive circuit.The experimental results show that the controller can effectively eliminate the zero lag.
What problem does this paper attempt to address?