Soft Sensoring Method for Concentration Measurement of Two-Phase Flow

WANG Bao-liang,HUANG Zhi-yao,CHEN Gong,LI Hai-qing
DOI: https://doi.org/10.3785/j.issn.1008-973x.2001.01.014
2001-01-01
Abstract:2-electrode capacitance systems for the concentration measurement of two-phase flow have inherently non-uniform sensitivity distributions over the cross section of the pipe and therefore have different response to different flow regimes. The change of flow regimes can lead to significant measurement errors. 12-electrode capacitance sensor based on tomography technique can give a measurement less flow-regime dependent but the algorithm is difficult to implement in microprocessor based instrument system. A new algorithm, based on artificial neural network, for the concentration measurement of two-phase flow is proposed. Considering the symmetry of the plates the structure of the neural network is simplified. Training set and test set are used to train the network. Test result shows the measurement error is less than 5 %.
What problem does this paper attempt to address?