Factors of Nonlinear-ultrasonic Detection and Its Application to HR3C Fireside Corrosion

QIN Peng,LI Ping,HOU Tian-yu,ZHAO Jie,LI Ting-ju
DOI: https://doi.org/10.11868/j.issn.1001-4381.2016.11.015
2016-01-01
Journal of Materials Engineering
Abstract:Based on the discussion of the factors influencing the nonlinear ultrasonic testing ,the feasi‐bility of nondestructive evaluation of HR3C fireside corrosion was investigated using nonlinear ultra‐sonic testing .The results show that the number of pulse string is no more than 2df/c and the installa‐tion of Hanning window is helpful to reduce the disturbance of the system ,in addition ,the rough sur‐face of the sample has a significant impact on the nonlinear parameter β.The nonlinear coefficient demonstrates a phased growth trend as corrosion time prolongs .At the initial stage of corrosion(with‐in 50h) ,there are small increments within 20% in the nonlinear coefficient ,however ,the nonlinear co‐efficient βis increased obviously with the duration time to 150h .Compared with un‐corroded sample , the amplification in the sample corroded for 200h reaches to 260% .The monotonous varieties in non‐linear coefficient are consistent with the aggravation of corrosion damage ,hence ,it is feasible to nonde‐structively evaluate HR3C fireside corrosion by means of ultrasonic nonlinear testing .