Abstract:The lowest order and origin of radial electromagnetic force were analyzed in electric machines with different slot-pole combinations and winding layers.The amplitudes of lowest order component of radial electromagnetic force in machines with the same number of slots but different number of poles were compared.The structrual finite element method was used to calculate the vibration of external rotor and the law of the lowest order of radial electromagnetic force was summarized.It is concluded that the slot-pole combination which produces lower order radial electromagnetic force may exhibit larger vibration of the machine;with the same number of slots,the vibration of the machine with more poles is larger than that with less poles.