Simultaneous Determination of the Cis-Isomer and L-Isomer in Nateglinide by HPLC

DONG Shubo,YANG Hanyue,CHEN Xuemin,YE Deju
DOI: https://doi.org/10.11973/lhjy-hx201803017
2018-01-01
Abstract:The sample (25 mg) was dissolved and the solution was diluted to 25 mL with a mixed solution of hexane-ethanol-trifluoroacetate (80+20+0.1).Chromatographic separation was achieved on a Chiralpak IG column (250 mm× 4.6 mm,5 μm),with a mixed solution of hexane-ethanol-trifluoroacetate (80 + 20 + 0.1) as mobile phase,at a fow rate of 0.8 mL · min-1.Diode array detector was used for determination at wavelength of 210 nm.Linear relationships were found between peak areas and mass concentraions of cis-isomer and L-isomer in the ranges of 0.024-4.392,0.050-4.040 mg · L-1,respectively,with detecion limits (3S/N) of 0.008,0.015 mg · L-1 respectively.Values of recovery obtained by standard additon method were in the range of 94.1%-99.3%,100% -104%,respectively,and RSDs (n=6) were less than 5.0%.
What problem does this paper attempt to address?