Study on the methods for test and evaluation of FOG’s scale factor and bias

Long ZHANG,Song YE,Shudao ZHOU,Xiaolei WANG,Feng LIU
DOI: https://doi.org/10.11857/j.issn.1674-5124.2016.12.001
2016-01-01
Abstract:In order to have an accurate evaluation on the performance of different types of interferometric fiber optic gyro (IFOG) used for the attitude and heading reference system (AHRS), the scale factor and bias test were implemented for two types of IFOG within the angular velocity range of [-35°/s, 35°/s] and data sampling frequency of 100 Hz, and the methods for parameter test and performance evaluation were also researched. The results showed that the scale factor nonlinearity of B-215 type IFOG which eliminated the singularities at ±20% was superior to KVH-13 type IFOG within the angular velocity range of [-35°/s,35°/s],and the scale factor nonlinearity of the two kinds of IFOG within the range was greater than that within the whole measuring range. However, the bias stability of KVH-13 type IFOG was superior to that of B-215 type IFOG under the sampling frequency of 100 Hz and the bias stability of B-215 type IFOG under the frequency was superior to its bias stability under the sampling frequency of 2 000 Hz. In conclusion, the test method can be used to obtain the performance parameters of IFOG under the specific measuring range and sampling frequency and it is conducive to improve the comparability of different types of IFOG products,which provide basis for model section of IFOG in practical application.
What problem does this paper attempt to address?