Experimental study and optimization of indoor leakage safety of R290 household air-conditioner

Zhifeng Zhong,Weier Tang,Xiaofang Zhou,Lijuan Niu,Keqiao Li,Changyun Guo,Guogeng He
DOI: https://doi.org/10.3969/j.issn.1000-6516.2017.02.010
IF: 2.134
2017-01-01
Cryogenics
Abstract:Many kinds of refrigerant leakage of household air conditioner were simulated.Experiments on the distribution of R290 in the room were carried out under different conditions,including two kinds of leak hole diameter of 0.5mm and 4mm,two charge quantities of 260g and 350g,and installation of solenoid valve on indoor and outdoor unit connecting pipes.The results show that the refrigerant charge quantity and the size of leak hole are critical to the room security.Furthermore,installing a solenoid valve on the connecting pipe can effectively reduce the R290 leak rate and enhance the safety of R290 split type household air conditioner.
What problem does this paper attempt to address?