Development and Optimization of a Novel Combined Heat Pump-Water Heater Combined Cycle System

Liming Xu,Xiaohua Wu,Yunkai Yue,Zhentao Zhang
DOI: https://doi.org/10.3969/j.issn.1671-6612.2017.04.023
2017-01-01
Abstract:To meet domestic demand for cooling and heating water,generally air conditioner and water heater are needed.Air conditioner will release heat of condensation in the summer,which will waste the energy and cause thermal pollution if it is not used.In order to make full use of the heat of condensation,a novel heat pump-water heater combined cycle system is proposed.According to the latest national standards,the indoor unit,outdoor unit,& water heater are designed and optimized.The novel system can improve the utilization and safety of the equipment compared to two independent systems.Compared with air conditioner & electric water heater,air conditioner & gas water heater,air conditioner & air-source heat pump water heater,the novel system initial investment can save 3.0%,14.8% and 38.1% and the operation costs can save 42.6%,35.0% and 28.9% respectively.
What problem does this paper attempt to address?