Wind-tunnel studies on the characteristics of indoor/outdoor airflow and pollutant exchange in a building cluster
Peng-Yi Cui,Yan Zhang,Wei-Qiu Chen,Jin-Hao Zhang,Yang Luo,Yuan-Dong Huang
DOI: https://doi.org/10.1016/j.jweia.2021.104645
IF: 4.437
2021-07-01
Journal of Wind Engineering and Industrial Aerodynamics
Abstract:The diffusion of air pollutants in urban areas is essentially a multiscale problem, which has aroused increasing concerns. Wind-tunnel experiments were employed to explore the characteristics of indoor/outdoor airflow and pollutant exchange in a building cluster. Under two wind directions (β = 0°,45°), smoke visualization tests were firstly conducted to visualize the diffusion characteristics of air pollutants released from different pollution sources. Then the 3D hot-film anemometer and SF6 quantitative detector were used to measure the turbulence parameters and pollutant distributions. The smoke visualization tests showed that under β = 0°, the pollutants were mainly concentrated in the middle main street canyons (S-1 and S-2), spread downstream, and were gradually diluted. However, the influence area under β = 45° was wider. The results confirmed that the indoor pollutant concentration along different floors was closely related to that around the outside target building. The window-opening mode had great influence on indoor pollutant concentration, but little influence on the other floors. Additionally, when the pollution source was located in the building leeward wake, regardless of the building height, it could reduce the indoor air quality of the leeward building. This study is helpful to understand the characteristics of flow and dispersion through different urban scales.
mechanics,engineering, civil