Abstract:In this paper,the 'U+Ⅰ' ventilation system's characteristics of fully mechanized top coal caving face have been analyzed and the air distribution formula of each roadway deduced.In addition,gas drainage efficiency of the 'U+I' ventilation system was investigated when the elevated lane was both blocked and unobstructed.And more specifically,the differences of the oxygen concentration field in the goaf caused by the elevated lane's state of the 'U+Ⅰ' ventilation system were studied with numerical simulation method and by combining the mine fire case dated April 8,2005 at the working face 5344 of Wulan Coal Mine,Shenhua-Ningxia Coal Industry Group.The research shows that if the elevated lane is blocked,the gas drainage efficiency would become lower and gas concentration at upper corner of working face would become higher.Besides,the oxidization and heat accumulation zone would be expected to be larger than before and nearer to the working face in the exhaust section.The results achieved may serve as a guidance to solve gas overrunning problem at work face and prevent coal spontaneous combustion in the goaf.