Determination of Trace Uranium by Differential Pulse Polarography

HE Wei,WANG Shou-xu,TANG Xian-zhong
DOI: https://doi.org/10.3969/j.issn.1000-7571.2006.01.013
2006-01-01
Abstract:UraniumⅥ reacts with 8-hydroxyquinoline(abbreviated 8-OX)to form a insoluble complex which is quantitatively absorbed on the surface of micro crystalline naphalene in the range of pH 4.2-8.2.The trace amounts of uranium is determined by differential pulse polarography on dropping mercury electrode after the complex is desorpted and soluted by dilute HCl.The detection limit of uranium is 0.02 μg/mL and the linear range is 0.05-15 μg/mL with correlation coefficient of 0.999 3 and relative standard deviation of 1.1%.Many parameters such as the effect of pH,volume of aqueous phase as well as interference of a number of salts anions and cations on the determination of uranium are also discussed.The method has been apllied to the determination of trace uranium in synthetic sample and industrial wastewater.
What problem does this paper attempt to address?