STUDY ON ELECTROCHEMISTRY CHARACTERISTICS IN MIC BY WIRE BEAM ELECTRODES

董泽华,郭兴蓬,刘宏芳,许立铭,郑家燊
DOI: https://doi.org/10.3969/j.issn.1005-4537.2002.01.011
2009-01-01
Abstract:Wire beam electrode(WBE) was applied to study the microbiologically influenced corrosion(MIC) of Q235 carbon steel associated with sulphate reducing bacteria(SRB) in semicontinuous culture medium(to be completely refreshed every 72 hours).The potential,galvanic current density and impedance mapping,as well as open circuit potential(OCP) and electrochemical impedance spectrum(EIS) were measured to predict the localized corrosion under biofilm during SRB growing.As a result,the OCP moved negatively gradually with time.However,The mapping showed the potential fluctuation on the WBE surface decreased over time due to the conductivity of FeS x ( x =0.9~2) metabolized by SRB in the biofilm.Therefore,the potential mapping could not be a criterion of localized corrosion under biofilm.Instead,the impedance mapping could give a good prediction to the MIC.In addition,The biofilm capacity moved up to a very large level(~10 5 μF/cm 2) in shape of sigmoid when SRB grew.At the same time,both solution resistance and charge transfer resistance decreased exponentially.
What problem does this paper attempt to address?