Numerical Simulation on Free Surface in the Mold of Slab Continuous Caster at Low Casting Speed with MFCD

Shaoyang Chu,Zhigang Zhao,Shengtao Qiu,Guifang Zhang
DOI: https://doi.org/10.15980/j.tzzz.2017.07.018
2017-01-01
Abstract:In order to understand influence of mold flow control device (MFCD) on mold free surface at low casting speed,based on the calculation theory of fluid mechanics,the 3D-mathmatical model of fluid flow in the continuous casting mold was established by the Fluent-software.The fluid flow in mould for slab continuous casting has been simulated using model of k-ε high Re equation.Under the conditions of different structural submerged entry nozzle,the effects of MFCD on mold free surface(temperature field and flow field) has been analyzed at low casting speed.The results show that effects of MFCD on mold free surface is related with submerged entry nozzle structure.The MFCD can reduce the turbulent kinetic energy of the free surface under the conditions of the 1 submerged entry nozzle,while it can increases the turbulent kinetic energy under the conditions of the 2 submerged entry nozzle.The MFCD(insertion depth of 50、100 mm) is not feasible for slab continuous casting at low casting speed(0.55 m/min).