Control Strategy for Current-source Converters under Unbalanced Network Voltage Conditions

LI Yu-ling,ZHANG Zhong-chao
DOI: https://doi.org/10.3321/j.issn:1000-1026.2005.16.013
2005-01-01
Abstract:This paper presents a new control strategy to eliminate second harmonic of dc output current in the 3-phase unbalanced network voltage PWM current-source converters (CSC). This proposed method can effectively reduce low order harmonics of the network current. The proposed method improves the traditional predictive controller and achieves good control performance. With application of current space vector modulation, the utilization of the devices is enhanced greatly. Also with this proposed scheme, current sensors are avoided, which results in cost down. Experimental results confirm the feasibility of the proposed method.
What problem does this paper attempt to address?