Secondary Release Characteristic of Mercury in Limestone Wet Flue Gas Desulfurization System

MENG Dongdong,WANG Xuan,YANG Tao,ZHANG Cheng
DOI: https://doi.org/10.3969/j.issn.1007-290X.2016.11.004
2016-01-01
Abstract:In allusion to the problem of limestone-gypsum wet flue gas desulfurization(WFGD)system being unable to remo-ving Hg0 ,this paper employs experiments for studying influence of changes of working conditions on mercury secondary re-lease such as initial mass concentration of Hg2+ in serous fluid,temperature and pH value of serous fluid,amount-of-sub-stance concentration of S(IV)and SO2-4 ,volume fraction of Cl- and addition of Na2 S and H2 O2. Results indicate initial mass concentration of Hg2+ and amount-of-substance concentration of SO2-4 has small influence on mercury secondary re-lease,rise of temperature and high pH value can reduce mercury secondary release and a small number of S in serous fluid will promote reduction of mercury. In addition,when there is Cl- in serous fluid or adding Na2 S and H2 O2 ,it is able to re-strain reduction of mercury.
What problem does this paper attempt to address?