Power Quality Disturbance Identification Based on Improved HHT and Decision Tree

Xiaona LI,Xinglai SHEN,Xue XUE,Rui LIANG
DOI: https://doi.org/10.3969/j.issn.1000-7229.2017.02.016
2017-01-01
Abstract:In order to accurately identify the type of power quality disturbance for the effective governance of power quality problems, this paper proposes a new identification method for power quality disturbance based on the improved Hilbert-Huang transform (HHT) and decision tree.Firstly, power quality disturbance signals are analyzed through HHT algorithm with the improved slope-based method (ISBM) inhibiting the endpoint effect.Then, the frequency components, the disturbance duration and the frequency during the disturbance duration can be extracted from the obtained instantaneous frequency curve.And from the instantaneous amplitude curve, the voltage amplitude during the disturbance duration can be obtained.Finally, by using these 4 characteristics as the judgment of the constructed decision tree, the disturbance signal is successfully classified and recognized.According to the mathematical model of each kind of power quality disturbance signal, a large number of samples are produced to conduct the simulation tests.The simulation results prove the effectiveness and accuracy of the proposed method.And compared with the existing two identification methods, the results show that this method has higher identification accuracy, which can identify the type of power quality disturbance quite accurately.
What problem does this paper attempt to address?