Study on Flame Stability of Swirl Coal Burner at High Load

成文俊,李争起,陈智超,秦裕琨
DOI: https://doi.org/10.3969/j.issn.1004-9649.2005.01.013
2005-01-01
Abstract:Since the swirl coal burners could not keep the flame stable at rated load in a 670 t/h lean coal-burned boiler, cold flow experiments were made in a single-phase test-bed. The experimental results showed that, the flameout at high load arose not from the changes of re-circulation zone and divergent angle, but from the mismatched primary air and swirl secondary air. When the cones between the swirl secondary air duct and the non-swirl secondary air duct in the burners were removed, the swirl secondary air velocity decreased and diffused around earlier, and the re-circulation zone length and divergent angle increased somewhat. The improved burner can resolve the flameout problem at high load. The impact of non-swirl secondary air ratio, the swirl secondary air ratio and the primary air on the flow field are also achieved.
What problem does this paper attempt to address?