Optimization methods for frequency modulation of thermal power units under the new normal state: a review

Huanyu LI,Feng YIN,Zhihao LUO,Bo CHEN,Jinlong LIAO,Wei LI,Deren SHENG
DOI: https://doi.org/10.19666/j.rlfd.201704002
2018-01-01
Abstract:New features of electricity supplement, transmission and consumption under the new normal circumstance, as well as their effects on frequency modulation (FM) were concluded. The contribution of flexible operation on frequency modulation was analyzed based on the experimental data, including condensed water throttling method, high pressure heater bypass method, additional steam valve method, cooling working medium method and cogeneration steam extraction method. The theory, advantages and disadvantages of the key factors of frequency modulation were discussed, including how to set the primary frequency modulation parameters, how to optimize the valve flow characteristics, how to solve the problems of frequency modulation compensation, frequency modulation antiregulation and estimation of frequency modulation ability. At last, a kind of multilevel frequency modulation strategy for thermal power plants was proposed to satisfy the need of flexible operation.
What problem does this paper attempt to address?