Digital synchronous rectification driving method for LLC resonant converter

Zheng-yu Lü,Jia-chen LI,Hua YANG
DOI: https://doi.org/10.15938/j.emc.2018.01.003
2018-01-01
Abstract:A digital synchronous rectification driving method for LLC resonant converter was proposed . This driving method was based on detection of the drain-source voltage of the synchronous rectifier MOS , and then conduction of the body diode was judged .Through the voltage comparator ,the output level was transferred to the digital processor ,and algorithm captures the turn-on time of the body diode and regu-lates the duty cycle of the driving signal of the synchronous rectifier tube ,so that the synchronous rectifi-cation achieves the ideal effect ,and the efficiency of the converter is improved .Compared with the tradi-tional synchronous rectification driving method ,it has the advantages of simple circuit structure and con-trol algorithm,accurate driving signal ,good dynamic performance and so on .In order to verify effective-ness of the proposed method ,a 72 W half bridge LLC resonant converter is used as the prototype ,and the efficiency is 97 .5%.
What problem does this paper attempt to address?