Sensorless Control Strategy of Doubly-Fed Induction Generator Connected to DC Grid

NIAN Heng,WU Chao
DOI: https://doi.org/10.15938/j.emc.2016.11.001
2016-01-01
Abstract:In order to simplify the complexity of doubly-fed induction generator ( DFIG) system connected to DC grid, the sensorless operation technique is further studied on the basis of two converters. Aiming at that stator voltage is not sinusoidal, the stator side converter and the rotor side converter was controlled through the indirectly air-gap flux orientation. In order to reduce the dependency on the parameters, the model reference adaptive system based on air-gap flux was applied to achieve the sensorless operation. The small signal method was applied to analyze the stability of the sensorless operation and the robustness against the DFIG parameter variations on the basis of mathematical model of DFIG. Finally, the experi-mental system of DFIG connected to DC grid is developed to validate the sensorless operation technique.