Temperature-Fluid Field Coupling Analysis of Three Phase Asynchronous Motor with Copper Rotor

Qixu CHEN,Yunhong WANG,Laishun YANG,Jun XU,Binggang CAO
DOI: https://doi.org/10.3969/j.issn.1673-6540.2017.10.014
2017-01-01
Abstract:A special three phase asynchronous motor applied to top drive facility was studied,which uses the compulsorily ventilation and non-standard design.Critical techniques,such as non-base design,ventilation hole of stator iron yoke,epoxy resin sealing at stator winding end,and squirrel-cage rotor composed of copper bars were adopted,which satisfy the strict requirements under the condition of frequent start and stop,overloading,and saltmist.Temperature-fluid field coupling model was established,and then the transient-state temperature trends and steady-state temperature distribution of the parts of motor under the rating condition were analyzed.The results of simulation and thermal rising test showed that the temperature in the axial direction was higher at the locations of the posterior segment,and testify that the temperature distribution has no local hot spot.At the same time,experiment verifies that the temperature-fluid field coupling model and result are reasonable,which satisfy the requirement of H level temperature rise.The effect of inlet pressure and ventilation hole diameter change on temperature rise were analyzed on the basis of coupling model,which provides the theoretic foundation for improving cooling structure of motor.
What problem does this paper attempt to address?