PRINCIPLE AND TRANSIENT RESPONSE CHARACTERISTICS OF PROTECTION TRANSIENT RADIANT HEAT FLUX METER

Chunchen Sheng,Peng Hu,Xiaofang Cheng,Zeshao Chen
DOI: https://doi.org/10.19912/j.0254-0096.2017.04.031
2017-01-01
Abstract:A novel protection transient radiant heat flux meter was developed for radiant heat flux measurement in vacuum environment.It was equipped with two thermal protection circles to make side faces of central heat receiver adiabatic.And the theoretical model of measurement principle was developed according to the structure and transient heat transfer equation.The measurement results of thermal infrared imaging camera show that the temperature distribution in the center of central heat receiver is uniform,which meets the requirement of the theoretical model.The transient radiant heat flux tests of black body furnace and Xenon lamp show that the heat flux meter has high measurement accuracy and good transient response characteristics.
What problem does this paper attempt to address?