Failure Modes of ZnO-based Varistor

Mao-hua WANG,Ke-ao HU,Nan-fa ZHANG
DOI: https://doi.org/10.3969/j.issn.1001-2028.2005.09.020
2005-01-01
Abstract:Studied were several failure modes frequently occurring in the production and application of zinc oxide varistors,including electrode-related failures,average power dissipation overstress failures,moisture degradation. The experiments discover the characteristics and mechanism of the above-mentioned failure modes,and the electrode’s resistence of varistors can be decreased by increasing its thickness; for the varistors used in surge protective devices,In=15 kA can be taken for the standard impulse current; the moisture degradation of varistors can not give rise to the electrical circuit failure,and the moisture degradation of varistors can be prevented by insulation treatment in the side.
What problem does this paper attempt to address?