Analysis of Phase-shift Full-bridge DC/DC Converter with Blocking Capacitor

SHEN Yan-qun,YAO Gang,HE Xiang-ning
DOI: https://doi.org/10.3969/j.issn.1000-100x.2005.03.005
IF: 5.967
2005-01-01
IEEE Transactions on Power Electronics
Abstract:Full-bridge DC / DC converter is widely used due to it′s high-usage of magnetic core and various control methods. Phase-shift control is usually used because ZVS can easily be achieved without additional switches. In order to avoid DC component current of the transformer,blocking capacitor is usually used in phase-shift full-bridge ZVS DC / DC converter in practical application.With the adding of the blocking capacitor,the operating principle of the converter is changed.The operating principle of the phase-shift full-bridge ZVS DC / DC converter with blocking capacitor is analyzed in this paper.The effect of blocking capacitor on the converter′s performance is especially investigated. Finally,the simulation is given,and a 2 kW prototype is built for experimental verification. It′s shown that the use of the blocking capacitor can reduce the duty-cycle loss,while it reduces the ZVS range of the lagging leg. And the voltage stress of the rectifier diodes is increased too.
What problem does this paper attempt to address?