Heavy-Duty Gas Turbine Modelling and Simulation basing on Simscape

Meng-meng XU,Yu-hao ZHU,Rui FENG,Yong-wen LIU
DOI: https://doi.org/10.3969/j.issn.1009-2889.2015.01.004
2015-01-01
Abstract:The amount of secondary air of modern heavy-duty gas turbine accounts for about 20%of total compressor flow, which has a significant influence on gas turbine.For fully using secondary air, Siemens installs control valve in part of secondary air loops to control flow, which is applied on SGT5-4000F and other gas turbine types.For the study of secondary air cooling control system, a common extensible gas turbine library and a heavy duty gas turbine model are built.A varying duty simulation experiment shows that secondary air cooling control system can optimize gas turbine overall performance by protecting turbine and improving compressor efficiency.
What problem does this paper attempt to address?