EXPERIMENT STUDY OF LOW NOX POSITIVE/OPPOSING CONCENTRIC TANGENTIAL FIRING SYSTEM IN A 300 MW PULVERIZED FUEL BOILER

ZHANG Hui-juan,HUI Shi-en,ZHOU Qu-lan,GAO Zhen-qiang,ZHAO Ke,Tao Ming
DOI: https://doi.org/10.3321/j.issn:0258-8013.2005.15.022
2005-01-01
Abstract:Particular model experiment was carried out to study the aerodynamic field of low NOx positive/opposing concentric tangential firing system in a 300MW pulverized fuel boiler. The effect of deflected secondary air and opposing primary air on the relative diameter of the tangential firing, rotation momentum flux, turbulence magnitude and the velocity variation in horizontal flueway and the effect of layout form of OFA on flow characteristics in furnace are analyzed. The experimental result shows that, concentric opposing tangential firing system and wall disposal high velocity OFA will be of help to lower NOx emission, ensure high efficiency of combustion, and lighten thermal variation of superheater and reheater.
What problem does this paper attempt to address?