Removal of Copper and Iron Ion from Transformer Oil by Liquid-Liquid Extraction

Yaohong Zhao,Shufang Zeng,Yihua Qian,Wei Su,Lisheng Zhong
DOI: https://doi.org/10.16790/j.cnki.1009-9239.im.2016.04.013
2016-01-01
Abstract:Excessive copper ions would lead to the increase of dielectric dissipation factor of transformer oil. So we used N-methyl-2-pyrrolidone (NMP)-water system to extract the copper and iron ions in transformer oil in this paper, studied the influence of extraction times, temperature, and water content on the liquid-liquid extraction effect, and analyzed the variation of additives content in the transformer oil and its electrical properties before and after extraction. The results show that the copper and iron ions content decrease obviously after three times of extraction, and the dielectric dissipation factor decreases greatly. The extraction system can be applied in wide range of temperature. The small content of water in the extraction system can enhance the removal ability of copper and iron ions. After liquid-liquid extraction, the additives content decline.
What problem does this paper attempt to address?