Design of discrete PR controller for single-phase grid-connected converter

Zongjian LI,Yuxing DAI,Chongwei ZHENG,Daqiang BI,Kecun GAO,Xueli SUI
DOI: https://doi.org/10.16652/j.issn.1004-373x.2014.17.014
2014-01-01
Abstract:Since the single-phase grid-connected Converter system with traditional PI controller has steady-state error in tracking the grid-connected current instruction,and traditional proportion resonant (PR) controller has defects of the resonant point shift in the discretization process,a new discrete proportion resonant(DPR)controller is proposed in this paper. The con-troller contains proportional,feedforward and resonant terms. A set of discrete second-order state equation is adopted for imple-mentation of the resonant term to replace the second-order differential equation of traditional PR controller after discretization. It can make the controller has non-static error characteristics. Compared with the traditional PR controller,DPR controller will not result in resonance point shift by discrete process and then affect controller performance because the resonant term is directly realized by the discrete state equation. The effectiveness of the method was verified by experiments.