Realization of frequency calibration for 532 nm wavelength laser based on spectral enhancement technology
Zhao Hanyu,Cao Shi-Ying,Dai Shao-Yang,Yang Tao,Zuo Ya-Ni,Hu Ming-Lie,,,
DOI: https://doi.org/10.7498/aps.73.20240106
IF: 0.906
2024-01-01
Acta Physica Sinica
Abstract:The iodine-stabilized 532 nm Nd:YAG laser plays an important role in the realization of the unit of length "meter (m)", absolute gravimeter, gravitational waves detaction, precision spectroscopy, distance metrology, and so on. Absolute frequency measurement and calibration of the laser are of great significance for the performance evaluation of the laser. The previous method of extending the erbium-doped fiber optical frequency comb (Er-FOFC) to the wavelength of 532nm was to first amplify the seed light, then frequency-doubled with a periodic polarization lithium niobate crystal, and finally couple it into a photonic crystal fiber to expand the spectrum to the 532nm band. With such technique, the a signal-to-noise ratio (SNR) of the beat signal between the iodine-stabilized 532 nm Nd:YAG laser and the Er-FOFC is approximately 30 dB. Moreover, the SNR of the beat signal was unstable, resulting in the errors in frequency measurement with a counter. This is not conducive to the long-term frequency measurement of the iodine-stabilized 532 nm Nd:YAG laser. Therefore, a method that can obtain both high SNR and long-term stable beat signals is required. In this paper, an Er-FOFC was developed. The spectral enhancement of its broadened at 1 μm was carried out, and then expanded to the wavelength at 532 nm with a frequency-doubling crystal. The output power of the Er-FOFC was 20 mW, which was first amplified to 370 mW by an Er-fiber amplifier and then compressed to a pulse width of 45.7 fs. Subsequently, the spectrum was extended to cover the wavelength at 1 μm with a highly nonlinear fiber, resulting in an output power of 180 mW. The broadened spectrum at 1 μm was amplified to 601 mW by a Yb-fiber amplifier, and the compressed power increasing to 420 mW. Using an MgO: PPLN crystal, the compressed laser was frequency-doubled to produce a 532 nm laser output with 155 mW power and a doubling efficiency of 36%. Utilizing this system, the absolute frequency measurements were conducted on the fundamental frequency light at 1064 nm and the doubled frequency light at 532 nm from the iodine-stabilized 532 nm Nd:YAG laser, yielding a beat signal with a SNR of greater than 40 dB. This SNR represents a 13 dB improvement compared with the results obtained when an amplified seed light is frequency-doubled using PPLN and then coupled into a PCF for direct spectral broadening to cover the 532 nm band. Over several days of continuous monitoring, there was no observed risk of SNR degradation. Moreover, subsequent frequency measurements were carried out continuously for over several hours, with the results maintaining consistency with recommended values.
physics, multidisciplinary