Abstract:The model of spectral filter of the nonlinear BBO crystal was constructed in a spectrall phase interferometry for direct electric field reconstruction(SPIDER) apparatus,and the bandwidth of the conversion efficiency for the BBO crystal with different prameters were calculated.The effects of the phase mismatch in the nonlinear BBO crystal and the thickness of the crystal on measuring the pulses with different bandwidth were demonstrated both theoretically and experimentally,and an optimization ratio of pulse width to crystal thickness was given.The BBO crystal with width of 50 μm should be optimal option for the 20 fs pulse,while the one with width of 100 μm for the 50 fs pulse should be sufficient.