Study on pH Sensor Based on Thin Excessively Tilted Fiber Grating

赵明富,邹文根,罗彬彬,邹雪,石胜辉,汤斌,徐杨非
DOI: https://doi.org/10.16818/j.issn1001-5868.2017.03.002
2017-01-01
Abstract:To improve the sensitivity and detection range of the current fiber optic pH sensors and reduce the effects of the cross-interaction of bending and temperature,the thin excessively tilted fiber grating (Thin-Ex-TFG) pH sensor coated with pH sensitive smart hydrogels for the sensitive membrane was put forward in this paper.We analyzed the factors that influenced the sensitivity in theory,and the scheme of improving the sensor's sensitivity was investigated.Finally,the Thin-Ex-TFG pH sensors coated with different thickness of hydrogels were fabricated and the corresponding experiments were carried out.The results showed that both of the sensitivity (up to-0.704 nm/pH) and response range (pH 2~7) of Thin-Ex-TFG pH sensor were increased,as compared with optical fiber Bragg grating pH sensor and long period fiber grating pH sensor;while compared with the standard diameter excessively tilted fiber grating with standard diameter,the sensitivity was also improved.The study revealed that appropriately increasing the coating thickness of smart hydrogels or reducing fiber grating cladding diameter can effectively increase the pH detection sensitivity,the experiment results agreed well with the theoretical analysis.
What problem does this paper attempt to address?