Closed orbit correction of hefei advanced light source (hals) storage ring*
Guangyao Feng,Lin Wang,Shancai Zhang,Weimin Li,Hongliang Xu,Congfeng Wu,Zuping Liu
2010-01-01
Abstract:In order to meet the increasing requirements of synchrotron radiation users, a new plan of VUV and soft X-ray light source, named Hefei Advanced Light Source (HALS), is brought forward by National Synchrotron Radiation Laboratory (NSRL). This 1.5GeV storage ring with ultra low emittance 0.2nmrad consists of 18 combined FBA cells and the circumference is 388m. Strong enough quadrupoles and sextupoles must be needed for getting such low emittance lattice, which will lead beam close orbit distortions’ (COD) sensitivity to the field and alignment errors in magnets. Estimation of the COD from various error sources is investigated. Using orbit response matrix and singular value decomposition method, the distribution of beam position monitors and the location of correctors are reported in the paper. Simulation proves that COD can be corrected down to 60 microns level. In the same time the corrector strengths are weaker enough in the correction scheme. INTRODUCTION Hefei Light Source (HLS) of National Synchrotron Radiation Laboratory is a dedicated second generation light source. In order to obtained synchrotron radiation with high brightness and better coherence in the VUV and soft X-ray range for users, A plane of building a new machine named HALS storage ring has been brought forward [1]. In the preliminary design, considering the required low emittance, the straight lines’ number and length, A FBA lattice structure with 18 super-periods has been chosen for HALS. Figure 1 shows the and dispersion functions of one cell, from which we can see there is no dispersion in straight sections. Main parameters about HALS storage ring can be founded in table1 [2]. In the design, strong quadrupoles and sextupoles have been used because of the low emittance lattice structure. The magnet alignment errors will lead to larger closed orbit distortion (COD), which can induce unwanted side effects. The non-linear effect can make the dynamic aperture and beam lifetime decreasing. Furthermore, it will change the synchrotron light’s position at the beamline front ends, which can influence the brightness at experiment station. In order to correct the COD, Beam Position Monitors (BPMs) and correctors must be installed. In the paper, COD is estimated considering alignment errors in magnets and girders. Magnets field errors are also included. Using SVD method, the closed orbit distortions are corrected. In the same time, corrector strengths and residual closed orbit distortions are obtained. Figure 1: and dispersion functions of one cell. Table 1: Main Parameters of HALS Storage Ring